July 30, 2019 at 1:45 PM
—
admin
Due to the electrolysis process, the floating calcium molecules get deposited on the cathode and the water returns to the process, reduction of calcium. Typical mineral scales in hot and cold domestic water distribution systems and also in evaporative cooling systems are largely calcium carbonate.
[More]
July 29, 2019 at 10:39 AM
—
admin
Electrochemical technology, wherein ElSr attains the chemical decomposition by electrical current. The treatment system to provide controlled electrolysis in a reaction chamber to…
[More]
516778f7-038c-4570-9665-6e8cb890f02d|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | OEM | Power plant | Self-Cleaning System | Tiaano
Tags: Electro Chemical, ElSr, Dcale Remover, Scale removal, bacteria, algae, slime, legionella, corrosion, blow down, evaporative, Natural draft cooling tower, Electrolysis, minerals, MGCO3, CACO3, Mg (OH)2, SIO2. Power Industries, Anode, Cathode
July 26, 2019 at 3:11 PM
—
admin
Savings minimum 20% of reject flow. 100% of blow down can be used for Gardening without further treatment as chemical contamination is not there in the blow down. Flow rate capacity (max.) of an ElSr reactor is one M3 / Hr. Tiaano ElSr-RO an electrolytic scale remover a single system producing strong oxidant, it can be taken care of protection on…
[More]
7743a09a-a100-4319-8961-18f32318e8f7|2|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Installation | Write ups | Application | Bio-fouling | General Information | RO Feed Pre - Treatment | Tiaano
Tags: storage tank, industries, power stations, refineries, water treatment, drinking water, corrosion, elsr, scale Remover, scale Removal, contamination, prevent legioneela, bacterial growth
July 24, 2019 at 6:33 PM
—
admin
The water is not soft at the outlet of the ElDs-Cl2, but the scale forming ions has been reduced to a level that prevents the precipitation in Water distribution system. ElDs-Cl2 will precipitate all scale forming ions, not just magnesium and calcium but other ions that are susceptible to dropping out the liquid at high pH Viz., Silica, Ferum, and Manganese etc.
[More]
July 22, 2019 at 6:15 PM
—
admin
It separates/observe the scale by using the principle of electrolysis without adding chemicals (zero chemical) and its below image is self-explanatory.
[More]
cb343066-2a91-4ef7-b580-b410f266967e|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Agriculture | Boiler feed water Pre-treatment | Broucher | Green House | Installation | Write ups | Application | Bio-fouling | cooling tower | General Information | Hot Water Treatment | Introduction | Power plant | RO Feed Pre - Treatment | STP Treated water | Tiaano
Tags: Tiaano, Elsr, electrolysis, zero chemical, STP treated water, Cooling tower, condenser, chillers, humidification spray chamber, pharmaceutical. drinking water, Agriculture, hot water Treatment, Ro feed water Pre-treatment system. de-scalant
July 10, 2019 at 10:35 AM
—
admin
Boiler water pH should be between 8.5 to 9.5, if failed to maintain the pH level, then the boiler water will start to make corrosion in the pipe lines of the boiler equipments.
[More]
July 1, 2019 at 6:43 PM
—
admin
The feed water should not be purified. The water should have minimum hardness and electrical conductivity, which will be speed up the process of electrolysis, resulting, effective scale separation. However, if the rust condition in the system is very serious, our ElSr can be used for removing rust also.
[More]