August 31, 2019 at 5:48 PM
—
admin
We Tiaano recommended Chemical Free Electrolytic Scale Remover system in the field of humidity chamber to enhance the performance of humidification Spray Chamber. It removes the scale by electrolytic operation with out adding chemicals (Zero Chemical). It generates Oxidants in the water; Oxidants mitigate the Corrosion, Bio-fouling, Micro-Organism growth, Scaling, & spread of airborne bacteria.
[More]
885d91d0-4dc2-401b-9cc8-71e177b6f593|2|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Green House | Humidification Spray Chamber | General Information
Tags: Tiaano, Electrolytic, Scale Remover, Moisture, Spray Chamber, Minerals, Nozzles, Humidification Plant, Chemical Free, Corrosion, Bio-Fouling, Micro-Organism, Bacteria, ElSr
August 30, 2019 at 3:07 PM
—
admin
Tiaano ElSr is an online treatment system, widely accepted product design for large capacity cooling towers in centralized AC, General Industries, Power stations, Refineries etc. It is a reliable turn-key project with trouble free operation 24 X7, functions electrolytic technology leads to zero chemical discharge on water treatment.
[More]
4bd3941a-a8e9-4838-b814-3ffbc2103719|2|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Broucher | Dairy Industry | Dis-infection | HVAC | Write ups | Application | Bio-fouling | General Information | Natural Draft cooling Tower | Power plant | Self-Cleaning System | STP Treated water | Tiaano
Tags: Scaling Problem, Cooling tower, Scaling, corossion, Micro biological activity, residual waste water, mineral, salt, calcium, Magnesium, fill, cooling tower fan, EiSr, water treatment, COC, Chemical, Electrolytic, Centralized AC< general Industries, Power stations, Refineries, Zero Chemical
August 28, 2019 at 3:26 PM
—
admin
COC means Cycle of Concentration. Normally one COC will take 2-3 Hrs. to complete, since there is a salt content in the water. Once the ElSr is installed, over a period of time this COC will be improved and it will take lesser time and also the electricity will be saved.
[More]
August 26, 2019 at 11:27 AM
—
admin
lSr system making the conductive salts in the water gets precipitated and ionized. So there may not be a difference, but the TDS will be ineffective. Due to this scale won’t be formed in the downstream water circuit. So it can’t be quantified.
[More]
55ec5164-7a4e-4587-8e04-eb579200fcb8|3|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Broucher | Dairy Industry | Dis-infection | HVAC | cooling tower | FAQ | General Information | Hot Water Treatment | Natural Draft cooling Tower | Power plant | RO Feed Pre - Treatment | Self-Cleaning System | STP Treated water | Tiaano
Tags: Scale Remover, ElSr, TDS, Hardness, salts, Conductive Salts, Conductivity, Temperature, Approach Value, Electrolyzer, Reactor, Anode, Cathode, BOD, COD, COCm
August 24, 2019 at 2:36 PM
—
admin
Make up water should not be softened. If it is softened there is no calcium or magnesium ions in the system, so hardness and electrical conductivity are so slow that the process of electrolysis will be slow and resulting in poor effect.
[More]
0a9bb432-01e9-4437-9f6d-91447cfea4d3|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Broucher | Dairy Industry | Dis-infection | Green House | Humidification Spray Chamber | HVAC | Installation | Photo Gallery | Application | Bio-fouling | cooling tower | Electrochlorination | FAQ | Natural Draft cooling Tower | Power plant | RO Feed Pre - Treatment | Self-Cleaning System
Tags: Make up water, feed water, Scale Remover, Scale Removal, Hardness, conductivity, electrolysis, bow down, Parameters, TDS, Recirculation flow, Cooling tower, Tiaano, Calcium, Magnesium
August 23, 2019 at 5:09 PM
—
admin
Tiaano incepted on 1992, and installed more than 5000 numbers of electrolytic water treatment system throughout 63 countries. Tiaano, India design and produce the Titanium reactor by “Make in India” concept.
[More]
0b1c29aa-e5ab-4eac-a3e5-e0ff25ed7d59|3|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Agriculture | Boiler feed water Pre-treatment | Broucher | Dairy Industry | Dis-infection | Green House | Humidification Spray Chamber | HVAC | Write ups | Application | Bio-fouling | cooling tower | General Information | Hot Water Treatment | Introduction | Natural Draft cooling Tower | OEM | Power plant | RO Feed Pre - Treatment | Self-Cleaning System
Tags: Tiaano, Chemical free, Titanium, water treatment, Scale Remover, Scale, algae, Legionella, alkaline, Corrosion, Cooling tower, Industries, Power Stations, refineries, Centralized Ac, Zero Chemical, blow down, approach value, Chiller, COC, Cycle of Concentration, contamination, chemical
August 22, 2019 at 12:34 PM
—
admin
The conditions of heat exchanger tubes before and after installation of “ElSr.” Previously , scale was adhering as much as heat exchanger tubes were blocked, but about half a year after installation , the adhesion status was significantly improved.
[More]
d5b5a2da-ddde-499e-a76a-8ea46cf5dedb|3|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Broucher | Dairy Industry | Dis-infection | HVAC | Bio-fouling | cooling tower | General Information | Natural Draft cooling Tower | Power plant | Self-Cleaning System | STP Treated water | Tiaano
Tags: Heat Exchanger, Tiaano, tubes, Oil coolers, Cooling tower, Cooling water systems, ElSr, Contaminant, Thermal efficiency, temperature, Non-Chemical
August 21, 2019 at 4:47 PM
—
admin
Electrolytic Contaminant Remover (ElCr) is a system for removing contaminants in the water and wastewater, where the water or wastewater is converted into treated water that can be discharged to the environment.
[More]
August 20, 2019 at 6:32 PM
—
admin
ElSr will precipitate all scale forming ions, not only Magnesium, Calcium but also Silicates (silica), Ferrites (ferum), Manganese and other cations which are all not removed by softeners.
[More]
2c498db6-81f4-4c84-85b1-016b4e6f4534|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Boiler feed water Pre-treatment | Broucher | Write ups | Application | Bio-fouling | General Information | RO Feed Pre - Treatment | Tiaano
Tags: Tiaano, ElSr, Scale remover, Magnesium, Calcium, Silicates, silica, Manganese, fouling, cleaning, UV irrradiation, RO membrane, chloride, Bacteria
August 19, 2019 at 10:53 AM
—
admin
Tiaano ElSr –Ro is an online treatment system, widely accepted product design for large capacity storage tanks in packaged drinking water, General Industries etc.
[More]