June 25, 2020 at 12:53 PM
—
admin
Scale available in the Cooling tower reservoir is composed of sodium and chloride. When DC is passed through the reactor to the electrolyte (water), the chlorides will disassociate and form chlorine.
[More]
3358f5b1-78ed-403f-af05-8c393cbc8898|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Non-Chemical Water Treatment | Water Treatment | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | Tiaano
Tags: Electro Chemical, pH, Reaction, Reactor, Corrosion, bacteria, anodes, Oxidant, disinfectant, Scale, Cooling Tower, Chlorides, Chlorine, DC current, NaoCl, Hydrogen, Sodium, Electrolyte, Saline water, ElSr, Chemical, Electrolysis
June 24, 2020 at 1:38 PM
—
admin
ElSr is an independent equipment, getting installed separately out of the Heat exchanger’s cooling water circuit. Water from the cooling tower reservoir is continuously circulated through the ElSr via circulation pump. Process of scale remover is getting carried out, when the ElSr is connected to power and water flow through it. Its construction is purely by using corrosion resistant materials of GRP, UPVC & Platinum group precious metal oxide coated titanium.
[More]
27fd4c52-0049-4c01-a0ef-1e0723fb5f60|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Anode | Broucher | Cathode | Dis-infection | ElectroChemistry | HVAC | Non-Chemical Water Treatment | Water Treatment | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | Introduction | Tiaano
Tags: Tiaano, Operation, Chemical, Chemical free, Heat exchanger, Water, Cooling tower, reservoir, Circulation pump, Scale Remover, ElSr, Titanium, UPVC, Platinum, Anode, Cathode, Calcium, Electro Chemical
June 10, 2020 at 10:14 AM
—
admin
Electrolytically removing scale involves developing an environment of high pH around the cathode,
[More]
8dc955b4-617c-409c-aaf8-288584fe6dd5|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Cathode | Dis-infection | ElectroChemistry | Water Treatment | Write ups | Application | cooling tower | Electrochlorination | General Information | Self-Cleaning System | Tiaano | Non-Chemical Water Treatment | Purchase Order
Tags: Cooling tower, Water Treatment, Chennai Metro, CMRL, Electrolytic, Scale Remover, disinfect, water, bio fouling, micro organism, Scale. Scale removal, heat exchangers
May 5, 2020 at 12:54 PM
—
admin
Water quality meets site-specific standards (may include conductivity, pH, hardness, alkalinity, silica, chloride anions, salt anions, sulfate anions, phosphate, copper, iron, and biological).
[More]
23b1c504-bf8d-4c0f-91f8-ba4537300cb9|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Water Treatment | Write ups | Application | Bio-fouling | cooling tower | General Information | Tiaano
Tags: Scale Remover, Tiaano, Make-up water, Blow down water, Chiller, energy, savings, corrosion, Conductivity, pH, Hardness, alkalinity, silica, Chloride, anions, salt anions, sulfate, phosphate, copper, iron, Cooling tower, Installation, Titanium, anode, Titanium anode, Chemicals, technology
April 20, 2020 at 4:35 PM
—
admin
‘Tiaano ElSr-ND’ is an online treatment system, widely accepted product design for large capacity cooling towers in Power station, Refinery etc. It is a reliable turn-key project with trouble free operation of 24 x 7, functions by Electrolytic technology leads Zero chemical usage on water treatment.
[More]
a93cdea2-4222-4854-bf6c-99c2e1a46db8|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Water Treatment | Write ups | Application | cooling tower | General Information | Natural Draft cooling Tower | Power plant | Self-Cleaning System | Tiaano
Tags: Chemical, Chemical free, Electrolyti, Scale Remover, Natural Draft Cooling Tower, Cooling Tower, Power stations, Refiney, Electrolytic technology, Water treatment, Suspended Solids, Contamination, Automatic, blow down, water, Savings.
March 23, 2020 at 11:02 AM
—
admin
Electrolytic Scale Removal.; Historic scales will be removed and collected.
[More]
ffc3b3be-854c-4efd-9b61-496eff8f5a08|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Installation | Water Treatment | Write ups | Application | cooling tower | General Information | Self-Cleaning System | Tiaano
Tags: Tiaano, Chemical, Chemical free, Scale Remover, Cooling tower, Self cleaning System, Self-Cleaning, Blow down, Savings on blowdown, COC, Make-up, Bacteria, Algae, Slime, Corrosion, Scale.
March 21, 2020 at 3:22 PM
—
admin
Tiaano has designed, Supplied and commissioned our Chemical free Self-cleaning Electrolytic Scale Remover in M/s. RKFL (Plant V).
[More]
March 10, 2020 at 10:35 AM
—
admin
Our technology was approved by the great M/s. Indian Space Research Organisation (ISRO) for the application of Hot water treatment.
[More]
4257d51f-33bb-4c77-8139-84d25f183314|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Approvals | Dairy Industry | Demo Kit | Dis-infection | HVAC | Installation | Photo Gallery | Write ups | Application | Case Study | cooling tower | General Information | Hot Water Treatment | Tiaano
Tags: Tiaano, Scale Remover, Cooling tower, hot water treatment, drinking water, India, Singapore, Vietnam, Performance Certificate, Performance, ISRO, AAVIN, Mahalunge, Drinking water.
February 26, 2020 at 4:07 PM
—
admin
nit responsibility of complete package by Tiaano. Unit means, responsibility for interfacing and successful operation of all components of ElSr supplied by Tiaano. Package includes…
[More]
7d31f86b-e0f6-417d-97bc-f69c0598b2f1|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Installation | Online Monitoring system | Photo Gallery | Write ups | Application | cooling tower | General Information | Self-Cleaning System | Tiaano
Tags: Tiaano, Chemical, Chemical free, Self-cleaning, Electrolytic, Scale Remover, Cooling Tower, Water treatment, Reactor, Electrolyser, Scraper, Scraper drive, Sanf filter, Pumps.
February 24, 2020 at 10:42 AM
—
admin
Zero chemical dozing: offered ElSr will eliminate the need of any dosing chemicals to treat the cooling water and substantially reduce the Bleed off (blow down) requirement by increasing Cycle of Concentration, thereby saving large quantity of make-up water.
[More]
973e6bf6-ad95-4fd2-83fa-897dc2093747|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Anode | Cathode | ElectroChemistry | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | Self-Cleaning System | Tiaano
Tags: Electrochemical, Technology, Tiaano, Chemical free, Self-cleaning, blow down, cycle of concentration, chemical, Make-up, ElSr, Anode, Cathode, algae, chloine, Bacteria, Watre, pH, Corrosion. Scale Remover, Acidic, Alkaline, Cooling water.