March 12, 2022 at 6:25 PM
—
admin
Chemical Free Electrolytic Scale Remover_ HWCS Tank_ Remover the deposited scale from the Heater_ testing of 650 Hrs with DC Voltage to ElSR_complete scales were removed and fell down inside the tank.
[More]
February 19, 2022 at 5:11 PM
—
admin
By using the electrodes, the water is electrolyzed using the DC Power for acting as an Antiscalant. Also the electrodes can be designed as per the customised design.
[More]
November 23, 2021 at 2:27 PM
—
admin
Chemical Free Electrolytic Scale Remover mainly used in Cooling Tower Utilities. This is working using the Electrolysis method, by feeding the water. Once the water enter into the Reactor using the DC Power it precipitate and electrolysed the water and generate the chlorine at anode and all the conductive materials which are key factor for scaling is deposit on the cathode. The attached image with alternative Anode & Cathode with scale are self explanatory.
[More]
November 23, 2021 at 2:27 PM
—
admin
Chemical Free Electrolytic Scale Remover mainly used in Cooling Tower Utilities. This is working using the Electrolysis method, by feeding the water. Once the water enter into the Reactor using the DC Power it precipitate and electrolysed the water and generate the chlorine at anode and all the conductive materials which are key factor for scaling is deposit on the cathode. The attached image with alternative Anode & Cathode with scale are self explanatory.
[More]
October 27, 2021 at 1:03 PM
—
admin
The processed water has been precipitated and ionised using the electrolysis method. The Chlorine is generated and protecting algae growth and disinfecting the small micro organisms. Also the conductive salts in the water has been removed using the caustic produced by the cathode of Electrolyser.
[More]
138d388d-693d-4fdc-ab1b-f7dd204f54bf|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Animation | Cathode | chemical free | chemical free self cleaning ElSr | Disinfecting the Bio Fouling | Dis-infection | disinfects the water | ElectroChemistry | Ionising Spray Chamber | Non-Chemical Water Treatment | Online Monitoring system | scale remover | self-cleaning | cooling tower | Electrochlorination
Tags: #ASHRAE #ISHRAE #Proof #Chemicalfree, #Chemicalfreetreatment, #conductivity, Calcim Carbonate, Calcium Remover, Cooing Tower Water Treatment, efficiency of chiller, heat exchangers, Micro biological activity, Micro organism, removing scale, remove historic scaling
September 24, 2021 at 4:31 PM
—
admin
Chemical Free Electrolytic Scale Remover (ElSr) is very much useful in the Chiller unit of HVAC Application. The system has been installed and enjoying the advantages of Less Blow Down, Algae free, Less Maintenance, increase in COC, reasonable approach value etc.
[More]
July 22, 2021 at 11:30 AM
—
admin
TIAANO's Chemical free self cleaning electrolytic scale remover water with hardness levels of 400-800 ppm prevent micro-organism growth like algae and slime.
[More]
July 15, 2021 at 3:08 PM
—
admin
Water quality meets site-specific standards (may include conductivity, pH, hardness, alkalinity, silica, chloride anions, salt anions, sulfate anions, phosphate, copper, iron, and biological).
[More]
July 15, 2021 at 1:58 PM
—
admin
SELF CLEANING CHEMICAL FREE ELECTROLYTIC SCALE REMOVER | Chemical Free Scale Remover using Electro Chemistry Method
[More]
May 10, 2021 at 5:20 PM
—
admin
Tiaano's ELECTROLYTIC SCALE REMOVER SYSTEM is a chemical free scale remover system. This is not just descaling the water circuit in cooling tower but also simulataneously disinfects the water so that the algae, fouling and growth of microorganisms is prevented so this are the advantage of tiaanos' chemical free self-cleaning electrolytic scale remover
[More]