July 11, 2020 at 11:19 AM
—
admin
RECENT ORDER FROM ITALY FOR CHEMICAL FREE RO FEED WATER PRE-TREATMENT
We Tiaano design, manufacturing & supplying Chemical free electrolytic Scale remover for RO feed water pre-treatment. Tiaano ElSr-RO an electrolytic scale remover a single system producing strong oxidant, it can be taken care of protection on….
i. Scale formation,
ii. Algae formation,
iii. Slime formation,
iv. Waterborne Bacterial growth,
v. Disinfection (prevent legionella),
vi. Creates an alkaline pH environment that prevents corrosion.
‘Tiaano ElSr-RO’ is an online treatment system, widely accepted product design for large capacity storage tanks in packaged drinking water, General industries, Power stations, Refineries etc.
Recently we got order from a pharmaceutical company from Italy. Below purchase order is self-explanatory.
19f7333b-8624-4881-b14f-99465c675d71|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Broucher | ElectroChemistry | Purchase Order | Water Treatment | Write ups | General Information | RO Feed Pre - Treatment | Tiaano
Tags: Tiaano, Chemical, Italy, RO, Feed water, Pre-treatment, Scale, Algae, Oxidant, drinking water, General Industries, Power Stations, Refineries, Pharmaceutical
June 24, 2020 at 1:38 PM
—
admin
ElSr is an independent equipment, getting installed separately out of the Heat exchanger’s cooling water circuit. Water from the cooling tower reservoir is continuously circulated through the ElSr via circulation pump. Process of scale remover is getting carried out, when the ElSr is connected to power and water flow through it. Its construction is purely by using corrosion resistant materials of GRP, UPVC & Platinum group precious metal oxide coated titanium.
[More]
27fd4c52-0049-4c01-a0ef-1e0723fb5f60|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Anode | Broucher | Cathode | Dis-infection | ElectroChemistry | HVAC | Non-Chemical Water Treatment | Water Treatment | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | Introduction | Tiaano
Tags: Tiaano, Operation, Chemical, Chemical free, Heat exchanger, Water, Cooling tower, reservoir, Circulation pump, Scale Remover, ElSr, Titanium, UPVC, Platinum, Anode, Cathode, Calcium, Electro Chemical
June 10, 2020 at 10:14 AM
—
admin
Electrolytically removing scale involves developing an environment of high pH around the cathode,
[More]
8dc955b4-617c-409c-aaf8-288584fe6dd5|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Cathode | Dis-infection | ElectroChemistry | Water Treatment | Write ups | Application | cooling tower | Electrochlorination | General Information | Self-Cleaning System | Tiaano | Non-Chemical Water Treatment | Purchase Order
Tags: Cooling tower, Water Treatment, Chennai Metro, CMRL, Electrolytic, Scale Remover, disinfect, water, bio fouling, micro organism, Scale. Scale removal, heat exchangers
April 20, 2020 at 4:35 PM
—
admin
‘Tiaano ElSr-ND’ is an online treatment system, widely accepted product design for large capacity cooling towers in Power station, Refinery etc. It is a reliable turn-key project with trouble free operation of 24 x 7, functions by Electrolytic technology leads Zero chemical usage on water treatment.
[More]
a93cdea2-4222-4854-bf6c-99c2e1a46db8|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Water Treatment | Write ups | Application | cooling tower | General Information | Natural Draft cooling Tower | Power plant | Self-Cleaning System | Tiaano
Tags: Chemical, Chemical free, Electrolyti, Scale Remover, Natural Draft Cooling Tower, Cooling Tower, Power stations, Refiney, Electrolytic technology, Water treatment, Suspended Solids, Contamination, Automatic, blow down, water, Savings.
February 24, 2020 at 10:42 AM
—
admin
Zero chemical dozing: offered ElSr will eliminate the need of any dosing chemicals to treat the cooling water and substantially reduce the Bleed off (blow down) requirement by increasing Cycle of Concentration, thereby saving large quantity of make-up water.
[More]
973e6bf6-ad95-4fd2-83fa-897dc2093747|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Anode | Cathode | ElectroChemistry | Write ups | Application | Bio-fouling | cooling tower | Electrochlorination | General Information | Self-Cleaning System | Tiaano
Tags: Electrochemical, Technology, Tiaano, Chemical free, Self-cleaning, blow down, cycle of concentration, chemical, Make-up, ElSr, Anode, Cathode, algae, chloine, Bacteria, Watre, pH, Corrosion. Scale Remover, Acidic, Alkaline, Cooling water.
February 4, 2020 at 12:07 PM
—
admin
Tiaano’s chemical Free Portable Scale Remover Installation at UPL, Jhagadia.
Tiaano has designed, fabricated, supplied and installed Chemical free portable Electrolytic Scale remover for cooling tower treatment at UPL, Jhagadia on Feb, 2019. We have installed our ElSr system for the cooling tower capacity of 750 TR. For 750 TR cooling tower, we have installed 11 Electrodes for the entire treatment of cooling tower. Tiaano, also made a frequent site visit by deputing an engineer to see the working condition of our ElSr. Our most recent site visit at UPL was on January, 2020 and found that, the ElSr system has been working well, and the below image is self-explanatory for the same.
Scale observed by our ElSr
After removing the scale:
January 29, 2020 at 10:32 AM
—
admin
Also, the chlorine produced by our anode helps to prevent the bacterial growth, algae formation, colony formation etc. The Electrolytic Scale Removal system to be capable of working in a maximum temperature of ~50°C.
[More]
e0de989a-0111-4abd-ae3b-65c13ec88200|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Anode | Cathode | Dis-infection | ElectroChemistry | Write ups | Application | Bio-fouling | cooling tower | General Information | Self-Cleaning System | Tiaano
Tags: Chemical, Electrolytic Scale Remover, Scale Remover, Non-chemical, Water trratmnet, dis-infect, conductive minerals, Cooling tower, Electrolyzers, anode, Cathode, Pump, corrosion, water, bacterial growth, alga, colony formation, temperature, chlorine
January 20, 2020 at 3:00 PM
—
admin
By this tool, the sedimented scale on the reactor wall which is absorbed by cathode is cleaned by friendly mode and it is made out of Steel.
[More]
c42b23d5-d764-4027-8b3e-e714400624ca|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Photo Gallery | Write ups | Bio-fouling | cooling tower | General Information | Self-Cleaning System | STP Treated water | Tiaano
Tags: Chemical free, Electrolytic, Cleaning, manual, Scale Remover, Cleaning Tool, Tiaano, Make-up, Chemicals, Cooling tower, dis-infection, Automatic, Self-cleaning, Manual filteration, Portable ElSr, Cathode, Scale
January 17, 2020 at 3:14 PM
—
admin
Blow down will be carried out on 8500 µS.
[More]
d9eadbec-5215-4ce9-8ee2-45be9eeb5400|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | ElectroChemistry | Photo Gallery | Write ups | Application | Bio-fouling | cooling tower | General Information | Self-Cleaning System | Tiaano
Tags: Tiaano, Chemical, Scale Remover, Cooling tower water treatment, Electrochemical, scale, bacteria, slime, corrosion, blow down, water, COC, Make-up
January 6, 2020 at 11:59 AM
—
admin
ElSr collect all free calcium carbonate and magnesium carbonate from the water and prevents any scale deposits on the cooling elements.
[More]
51c85586-ea9d-469d-928f-d9815d33bbf2|0|.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Broucher | Dis-infection | ElectroChemistry | Write ups | Application | Bio-fouling | cooling tower | General Information | Introduction | Tiaano
Tags: Scale Remover, Cooling Tower, Water treatment, Scale, corrosion, Bio-fouling, algae, electricity, Water Consumption, Cooling, efficiency, equipment, scaling, legionella, sunlight, chemical, softening, Tiaano, Electrolysis, algae.