September 24, 2019 at 4:53 PM
—
admin
Platinum group precious Mixed Metal Oxide (MMO) coated titanium electrodes for Oxygen rich with slight Chlorine effect.
[More]
a4a55dca-5211-4082-bed7-a0580641f862|3|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | Write ups | Application | Bio-fouling | Case Study | cooling tower | Self-Cleaning System | Tiaano
Tags: Tiaano, ElSr, Reactor, Cooling tower, Water Treatment, MMO, Titanium, Electrodes, Titanium Electrodes, Chlorine, area, density, Water Conductivity, Cathodes, NaOH, alkaline, pH, Electrical Conductivity, Power Consumption, Plastic, Corrosion, Shell, reinforced Plastic
September 20, 2019 at 4:04 PM
—
admin
Electrolytic Scale Remover (ElSr) unit is nothing but an electro chemical reactor which perform against Bio fouling & Scaling without adding any external reagents. Tiaano conducted various field study on energy saving, while using Tiaano ElSr in Cooling Tower water treatment.
[More]
3d1ffdbe-5565-41a2-9559-91d77d5c9947|2|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Dis-infection | Write ups | Application | Bio-fouling | Case Study | cooling tower | Desalination | General Information | Tiaano
Tags: Heat Transfer Efficiency, ElSr, Power Conservation, Electrolytic Scale Remover, Bio fouling, Scaling, energy saving, Tiaano, Water Treatment, Cooling tower, Condenser, heat exchanger, chilled water, Coolant, Evaporator, Compressor, Chilled water Pump, Pump, Minerals, Condenser tubes, Fouling, loss in heat transfer, Calcium carbonate, Microbiological film, Calcium sulphate, Magnesium phospate, magnetic ion oxide
September 19, 2019 at 5:59 PM
—
admin
PERFORMANCE REPORT ON TIAANO’S CHEMICAL FREE ELECTROLYTIC SCALE REMOVER, BY M/S. AAVIN TAMILNADU, MADHAVARAM, CHENNAI.
Project: Tamil Nadu Co-operative Milk Producers’ Federation (TCMPF) was formed in February’1981, to manage the activities such as milk procurement, storage, processing and marketing of the milk and milk products. They believes that our Country’s socio-economic development in connect with the development of rural India. The TCMPF Limited is an apex body of 17 District Cooperative Milk Producers' Unions. It is headquartered located at Aavin Illam, Madhavaram, Chennai and has four dairy plants in Chennai.
Application: Depending on the atmospheric temperature, Milk enters the receival vat between 80° F. and 98° F., and ideally it should be cooled immediately to about 40° F. to reduce the activity of the bacteria. Most of the plants do not have refrigeration system and cooling is done by passing the milk over a washboard type of cooler through which cold water is flowing. Natural water supplies are usually not cold enough without some form of cooling and are often in short supply. In such cases water cooling towers should be installed to get an efficient way of lowering the temperature of milk and improving the quality.
Due to the recirculation of water in the process, the mineral (Conductive Salts) which is found in the water causes more problems (Scaling) in their cooling water circuits. In order to resolve this problem, M/s. TCMPF are using Tiaano’s Chemical Free Electrolytic Scale Remover (ElSr) with the Model of Tiaano ElSr-CT / 300.
Results / Benefits: The following points are observed by M/s. TCMPF when using our Tiaano chemical free Electrolytic Scale Remover.
Ø 100% chemical dosing has been stopped.
Ø Blowdown has been reduced 20% than earlier become of Tiaano ElSr systems.
Ø Electricity consumption has been reduced, in the chiller and cooling tower fan.
&Osl...
[More]
September 18, 2019 at 5:41 PM
—
admin
Tiaano ElSr is an automatic and reliable turnkey system.
[More]
746ef3d7-c1b9-400a-a2a9-6ef65b042b0c|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c
Posted in: Bio-fouling | cooling tower | General Information | Self-Cleaning System | Tiaano
Tags: Tiaano, ElSr, Cooling tower, Water treatment, automatic, basin water, Chemical Treatment, bow-down, equipment, blow-down, Sand Filter, Self-cleaning, bacteria, algae, tower, scale, consumables, bleed control, COC, irrigation, Slime, Bio-fouling, alkaline, Chemical Free, legionella.
September 17, 2019 at 6:41 PM
—
admin
We Tiaano Successfully Completed a Portable Scale Remover Installation at Jaipur On Sep, 2019.
[More]
September 16, 2019 at 6:17 PM
—
admin
Tiaano is the only company design and fabricate the ElSr and its electrolyzer (Anode & Cathode assembly) for cooling tower application in PAN India.
[More]
September 14, 2019 at 12:29 PM
—
admin
20% of the water in circulation from the main stream will be tapped to our ElSr through non-destructive ultrasonic flow meter as an installation tool. By using this tool, control valve shall be adjusted
[More]
September 13, 2019 at 1:35 PM
—
admin
It is a Green Technology & Environment friendly.
[More]
September 11, 2019 at 3:19 PM
—
admin
Tiaano ElSr is having the provision of automatic control by a PLC with an interactive display/HMI for monitoring of ElSr operation. Alternately the HMI system shall have the option to be operated locally also.
[More]
September 10, 2019 at 5:58 PM
—
admin
Minimum required Electrical conductivity should be 500 Micro Siemens/cm. And the allowable conductivity for blow down is till 4500 Micro Siemens/cm.
[More]